Chest anteroposterior diameter measurement: Comparison of ultrasonic and manual methods across different BMI categories

dc.contributor.authorMuralidharan, C.
dc.contributor.authorJobin Christ, M. C.
dc.date.accessioned2026-07-23T14:07:06Z
dc.date.issued2026-01-30
dc.description.abstractChest anteroposterior diameter (APD) measurement is a critical metric in evaluating thoracic dimensions, particularly in assessing conditions like pectus excavatum and guiding interventions such as laryngoscopy and cardiopulmonary resuscitation. The lateral distance measurement of the thoracic cavity using the computed tomography image provides APD, but they expose the subject to radiation. Though the manual method of chest APD measurement using a wooden ruler is radiation-free, it is time-consuming and prone to human errors. This study proposes a novel and radiation-free method of measuring chest APD using an ultrasonic sensor. The accuracy and reliability of the measured chest APD using the ultrasonic method were compared with the manual method across three distinct BMI categories of 150 participants. The measured chest APD using ultrasonic and manual methods for underweight, normal, and obese participants ranges from 17-18 cm, 18.5-20.5 cm, and 23.75-25 cm, respectively. The statistical analyses, including paired t-tests and intra-class correlation coefficients (ICC), were performed to assess agreement between the two methods. The paired t-test manifests no significant difference between the mean APD measured using ultrasonic and manual methods with p-values of 0.8742 (underweight), 0.7390 (normal), and 0.7998 (obese). The ICC values obtained from the intra- and inter-observers for the ultrasonic and manual methods were ICC ≥ 0.93, 0.80 ≤ ICC ≤ 0.82 and 0.91, and 0.78. The ICC value obtained from the intra- and inter-observers for the ultrasonic method was high, so the ultrasonic method is better than the manual method. This study concludes that the ultrasonic method provides a radiation-free alternative to the manual method, making it suitable for routine clinical use globally.
dc.identifier.citationVol.53(4)p.437-445
dc.identifier.doi10.4038/jnsfsr.v53i4.12659
dc.identifier.issn2362-0161
dc.identifier.issn1391-4588
dc.identifier.urihttps://viduketha.nsf.gov.lk/handle/123456789/18733
dc.identifier.urihttps://doi.org/10.4038/jnsfsr.v53i4.12659
dc.language.isoen
dc.publisherNational Science Foundation: Colombo
dc.relation.ispartofJournal of the National Science Foundation of Sri Lanka
dc.subjectArduino Uno
dc.subjectBody mass index
dc.subjectChest anteroposterior diameter
dc.subjectPaired t-test
dc.subjectUltrasonic sensor.
dc.titleChest anteroposterior diameter measurement: Comparison of ultrasonic and manual methods across different BMI categories
dc.typeArticle
dspace.entity.typePublication
oaire.citation.issue4
oaire.citation.volume53

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
JNSF_V53_I4_P437-445.pdf
Size:
3.15 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed to upon submission
Description: